• AC High - Voltage SF6 Ring Main Unit
AC High - Voltage SF6 Ring Main Unit
discuss personally
Model
XGN15-12
Basic info
Brand ROCKWILL
Model NO. AC High - Voltage SF6 Ring Main Unit
Rated voltage 12kV
Rated frequency 50/60Hz
Series XGN
Product Detail
Product Description
XGN15-12 type AC high-voltage sulfur hexafluoride (SF₆) ring main unit (hereinafter referred to as the ring main unit) features remarkable characteristics such as small size, light weight, attractive appearance, easy operation, long service life, high parameters, no pollution and low maintenance requirements.
It is widely used in industrial and mining enterprises, high-rise buildings, residential communities, schools, etc., for 10KV power distribution systems as ring network power supply and terminal power distribution.
The ring main unit is equipped with SF₆ load switches or SF₆ load switch-fuse combination electrical appliances, which can close and break rated load current, close rated short-circuit current, and break transformer no-load current. When the combination electrical appliance is equipped with a fuse, it can break 31.5KA short-circuit current in one go, playing a role in controlling and protecting the power system.
Product Advantages
Unaffected by environmental factors during operation:
All live components are enclosed in a sealed housing, protecting against moisture, pollution, corrosive gases and vapors, dust, and small animals.

High safety for operators and high reliability:
Busbars on the switchgear assembly are located in the SF6 gas chamber, and connections between units use insulated plug-in solid busbars.
Resin-cast and insulated single-phase fuses are installed outside the switchgear enclosure, thus reliably preventing phase-to-phase faults.

Easy installation and expansion, no on-site SF6 gas filling required:
Various cabinets are made into single-cabinet fully enclosed structures, which can be combined in the factory or on-site according to requirements.
The switchgear cabinet of our company is made of aluminum-zinc coated steel plates, processed by CNC machine tools and riveted together, with good airtightness and reliability.
Compact structure requiring small space.
Lifetime maintenance-free.

The XGN15-12 type unitary ring network switchgear produced by our company has a cabinet made of aluminum-zinc coated steel plates processed by CNC machine tools and riveted together. Compared with products from traditional enterprises, it has a more beautiful appearance, a stronger cabinet, and more stable performance. Moreover, the SF6 ring network cabinet has many advantages such as small size (375mm in width × 1400mm in height × 980mm in depth), simple structure, maintenance-free operation, and reasonable price, which are highly favored by the market. Our company's users are distributed in more than 30 provinces and cities across the country except Tibet and Taiwan: it is widely used in Beijing, Shanghai, Tianjin, Chongqing, Guangzhou, Chengdu, Shenyang, Wuhan, Xi'an, Hunan, Zhejiang, Jiangsu, Shandong, Shanxi and other places, and has consistently received praise from users.
Switchgear Structure
Note: The XGN15-12 type unitary sulfur hexafluoride ring network cabinet consists of the following 4 parts:
① Busbar chamber ② Main switch ③ Cable chamber ④ Operating mechanism, interlocking mechanism and low-voltage control
① Busbar chamber
The busbar chamber is arranged in the upper part of the cabinet. In the busbar chamber, the main busbars are connected together and run through the entire row of switchgears.
② Load switch
The switch chamber is equipped with a sulfur hexafluoride load switch (FLN36 or FLN56). The outer shell of the load switch is made of epoxy resin casting, filled with sulfur hexafluoride (SF6) gas as the insulation medium, and there is an observation hole on the shell. An SF6 gas density gauge or a gas density device with alarm contacts can be installed in the switch chamber according to customer requirements.
③ Cable chamber
The load switch cabinet has a spacious cable chamber, mainly used for cable connections, allowing single-core or three-core cables to be connected using the simplest non-shielded cable lugs. At the same time, the ample space can also accommodate lightning arresters, current transformers, lower earthing switches and other components. According to standard design, the cabinet door is equipped with an observation window and a safety interlock device. The bottom plate of the cable chamber is equipped with a sealing cover and appropriately sized cable clamps with support frames. The bottom plate of the cable chamber and the front door frame can be removed to facilitate cable installation.
④ Operating mechanism, interlocking mechanism and low-voltage control room
The low-voltage room with interlock also functions as a control panel. The low-voltage room is equipped with a spring operating mechanism with a position indicator and a mechanical interlocking device. It can also be equipped with auxiliary contacts, trip coils, emergency trip mechanisms, capacitive live line indicators, key locks and electric operating devices. At the same time, the space in the low-voltage room can be used to install control circuits, metering instruments and protection relays. The 750mm wide cabinet is equipped with two identical low-voltage rooms, which can accommodate more accessories.
The entire XGN15 switchgear can be divided into upper and lower parts. The upper part of the cabinet includes the busbar chamber, load switch, operating mechanism and low-voltage room, which is separated from the lower cable chamber. Therefore, equipment installed in the upper unit can be inspected, modified safely and conveniently, and the entire upper unit can be replaced.
 
 
Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!